The Fermi National Accelerator Laboratory (FNAL) Muon g-2 Experiment has measured the anomalous precession frequency aμ(gμ-2)/2 of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by systems and calibrated in terms of the equivalent proton spin precession frequency in a spherical water sample at 34.7C. The measured field is weighted by the muon distribution resulting in ωp′, the denominator in the ratio ωa/ωp′ that together with known fundamental constants yields aμ. The reported uncertainty on ωp′ for the Run-1 data set is 114 ppb consisting of uncertainty contributions from frequency extraction, calibration, mapping, tracking, and averaging of 56 ppb, and contributions from fast transient fields of 99 ppb.
The Fermi National Accelerator Laboratory has measured the anomalous precession frequency aμ=(gμ−2)/2 of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by nuclear magnetic resonance systems and calibrated in terms of the equivalent proton spin precession frequency in a spherical water sample at 34.7∘C. The measured field is weighted by the muon distribution resulting in ω~′p, the denominator in the ratio ωa/ω~′p that together with known fundamental constants yields aμ. The reported uncertainty on ω~′p for the Run-1 data set is 114 ppb consisting of uncertainty contributions from frequency extraction, calibration, mapping, tracking, and averaging of 56 ppb, and contributions from fast transient fields of 99 ppb.
Magnetic-field measurement and analysis for the Muon g−2 Experiment at Fermilab
Lusiani, A.Membro del Collaboration Group
;
2021
Abstract
The Fermi National Accelerator Laboratory (FNAL) Muon g-2 Experiment has measured the anomalous precession frequency aμ(gμ-2)/2 of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by systems and calibrated in terms of the equivalent proton spin precession frequency in a spherical water sample at 34.7C. The measured field is weighted by the muon distribution resulting in ωp′, the denominator in the ratio ωa/ωp′ that together with known fundamental constants yields aμ. The reported uncertainty on ωp′ for the Run-1 data set is 114 ppb consisting of uncertainty contributions from frequency extraction, calibration, mapping, tracking, and averaging of 56 ppb, and contributions from fast transient fields of 99 ppb.File | Dimensione | Formato | |
---|---|---|---|
PhysRevA.103.042208.pdf
accesso aperto
Descrizione: articolo pubblicato
Tipologia:
Published version
Licenza:
Creative Commons
Dimensione
6.51 MB
Formato
Adobe PDF
|
6.51 MB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.