Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
The photon spectrum in B -> X-s gamma decay, where X-s is any strange hadronic state, is studied using a data sample of 88.5x10(6) e(+)e(-)->Upsilon(4S)-> B(B) over bar decays collected by the BABAR experiment at the Stanford Linear Accelerator Center. The partial branching fraction, Delta B(B -> X-s gamma)=(3.67 +/- 0.29(stat)+/- 0.34(syst)+/- 0.29(model))x10(-4), the first moment < E-gamma >=2.288 +/- 0.025 +/- 0.017 +/- 0.015 GeV, and the second moment < E-gamma(2)>=0.0328 +/- 0.0040 +/- 0.0023 +/- 0.0036 GeV2 are measured for the photon energy range 1.9 GeV < E-gamma < 2.7 GeV. They are also measured for narrower E-gamma ranges. The moments are then fit to recent theoretical calculations to extract the heavy quark expansion parameters m(b) and mu(2)(pi) and to extrapolate the partial branching fraction to E-gamma > 1.6 GeV. In addition, the direct CP asymmetry A(CP)(B -> Xs+d gamma) is measured to be -0.110 +/- 0.115(stat)+/- 0.017(syst).
The photon spectrum in B-->Xs gamma decay, where Xs is any strange hadronic state, is studied using a data sample of 88.5 x 10(6) e+ e- --> Upsilon(4S) --> BB decays collected by the BABAR experiment at the Stanford Linear Accelerator Center. The partial branching fraction, DeltaB(B --> Xs gamma) = (3.67+/-0.29(stat)+/-0.34(syst)+/-0.29(model)) x 10(-4), the first moment = 2.288+/-0.025+/-0.017+/-0.015 GeV, and the second moment E2(gamma) = 0.0328+/-0.0040+/-0.0023+/-0.0036 GeV2 are measured for the photon energy range 1.9 GeV < E gamma < 2.7 GeV. They are also measured for narrower E gamma ranges. The moments are then fit to recent theoretical calculations to extract the heavy quark expansion parameters m(b) and mu2(pi) and to extrapolate the partial branching fraction to E gamma > 1.6 GeV. In addition, the direct CP asymmetry A(CP)(B-->X(s+d gamma) is measured to be -0.110+/-0.115(stat)+/-0.017(syst).
Measurement of the branching fraction and photon energy moments of B -> X-s gamma and A(CP)(B -> Xs+d gamma) RID C-2728-2008 RID C-5223-2009 RID G-6312-2011 RID C-5719-2008 RID D-1055-2009 RID A-2675-2009
The photon spectrum in B-->Xs gamma decay, where Xs is any strange hadronic state, is studied using a data sample of 88.5 x 10(6) e+ e- --> Upsilon(4S) --> BB decays collected by the BABAR experiment at the Stanford Linear Accelerator Center. The partial branching fraction, DeltaB(B --> Xs gamma) = (3.67+/-0.29(stat)+/-0.34(syst)+/-0.29(model)) x 10(-4), the first moment = 2.288+/-0.025+/-0.017+/-0.015 GeV, and the second moment E2(gamma) = 0.0328+/-0.0040+/-0.0023+/-0.0036 GeV2 are measured for the photon energy range 1.9 GeV < E gamma < 2.7 GeV. They are also measured for narrower E gamma ranges. The moments are then fit to recent theoretical calculations to extract the heavy quark expansion parameters m(b) and mu2(pi) and to extrapolate the partial branching fraction to E gamma > 1.6 GeV. In addition, the direct CP asymmetry A(CP)(B-->X(s+d gamma) is measured to be -0.110+/-0.115(stat)+/-0.017(syst).
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11384/3619
Citazioni
ND
69
59
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.