We perform the first measurement on the D0-D0 mixing parameters using a time-dependent amplitude analysis of the decay D0→π+π-π0. The data were recorded with the BABAR detector at center-of-mass energies at and near the υ(4S) resonance, and correspond to an integrated luminosity of approximately 468.1 fb-1. The neutral D meson candidates are selected from D∗(2010)+→D0πs+ decays where the flavor at the production is identified by the charge of the low-momentum pion, πs+. The measured mixing parameters are x=(1.5±1.2±0.6)% and y=(0.2±0.9±0.5)%, where the quoted uncertainties are statistical and systematic, respectively.
Measurement of the neutral D meson mixing parameters in a time-dependent amplitude analysis of the D0 to π+π−π0 decay
Lees, J. .p.;Poireau, V.;Tisserand, V.;Grauges, E.;Palano, A.;Eigen, G.;Brown, D. .n.;Kolomensky, Y.u. G.;Koch, H.;Schroeder, T.;Hearty, C.;Mattison, T. .s.;Mckenna, J. .a.;So, R. .y.;Blinov, V. .e.;Buzykaev, A. .r.;Druzhinin, V. .p.;Golubev, V. .b.;Kravchenko, E. .a.;Onuchin, A. .p.;Serednyakov, S. .i.;Skovpen, Y.u. I.;Solodov, E. .p.;Todyshev, K. Y.u.;Lankford, A. .j.;Gary, J. .w.;Long, O.;Eisner, A. .m.;Lockman, W. .s.;Panduro Vazquez, W.;Chao, D. .s.;Cheng, C. .h.;Echenard, B.;Flood, K. .t.;Hitlin, D. .g.;Kim, J.;Miyashita, T. .s.;Ongmongkolkul, P.;Porter, F. .c.;Röhrken, M.;Huard, Z.;Meadows, B. .t.;Pushpawela, B. .g.;Sokoloff, M. .d.;Sun, L.;Smith, J. .g.;Wagner, S. .r.;Bernard, D.;Verderi, M.;Bettoni, D.;Bozzi, C.;Calabrese, R.;Cibinetto, G.;Fioravanti, E.;Garzia, I.;Luppi, E.;Santoro, V.;Calcaterra, A.;de Sangro, R.;Finocchiaro, G.;Martellotti, S.;Patteri, P.;Peruzzi, I. .m.;Piccolo, M.;Zallo, A.;Passaggio, S.;Patrignani, C.;Bhuyan, B.;Mallik, U.;Chen, C.;Cochran, J.;Prell, S.;Ahmed, H.;Gritsan, A. .v.;Arnaud, N.;Davier, M.;Le Diberder, F.;Lutz, A. .m.;Wormser, G.;Lange, D. .j.;Wright, D. .m.;Coleman, J. .p.;Gabathuler, E.;Hutchcroft, D. .e.;Payne, D. .j.;Touramanis, C.;Bevan, A. .j.;Di Lodovico, F.;Sacco, R.;Cowan, G.;Banerjee, S.w.;Brown, D. .n.;Davis, C. .l.;Denig, A. .g.;Fritsch, M.;Gradl, W.;Griessinger, K.;Hafner, A.;Schubert, K. .r.;Barlow, R. .j.;Lafferty, G. .d.;CENCI, RICCARDO;Jawahery, A.;Roberts, D. .a.;Cowan, R.;Cheaib, R.;Robertson, S. .h.;Dey, B.;Neri, N.;Palombo, F.;Cremaldi, L.;Godang, R.;Summers, D. .j.;Taras, P.;De Nardo, G.;Sciacca, C.;Raven, G.;Jessop, C. .p.;Losecco, J. .m.;Honscheid, K.;Kass, R.;Gaz, A.;Margoni, M.;Posocco, M.;Rotondo, M.;Simi, G.;Simonetto, F.;Stroili, R.;Akar, S.;Ben Haim, E.;Bomben, M.;Bonneaud, G. .r.;Calderini, G.;Chauveau, J.;Marchiori, G.;Ocariz, J.;Biasini, M.;Manoni, E.;Rossi, A.;Batignani, G.;Bettarini, S.;Carpinelli, M.;Casarosa, G.;Chrzaszcz, M.;Forti, F.;Giorgi, M. .a.;LUSIANI, Alberto;Oberhof, B.;Paoloni, E.;Rama, M.;Rizzo, G.;Walsh, J. .j.;Smith, A. .j. .s.;Anulli, F.;Faccini, R.;Ferrarotto, F.;Ferroni, F.;Pilloni, A.;Piredda, G.;Bünger, C.;Dittrich, S.;Grünberg, O.;Heß, M.;Leddig, T.;Voß, C.;Waldi, R.;Adye, T.;Wilson, F. .f.;Emery, S.;Vasseur, G.;Aston, D.;Cartaro, C.;Convery, M. .r.;Dorfan, J.;Dunwoodie, W.;Ebert, M.;Field, R. .c.;Fulsom, B. .g.;Graham, M. .t.;Hast, C.;Innes, W. .r.;Kim, P.;Leith, D. W. G. S.;Luitz, S.;Luth, V.;Macfarlane, D. .b.;Muller, D. .r.;Neal, H.;Ratcliff, B. .n.;Roodman, A.;Sullivan, M. .k.;Va’Vra, J.;Wisniewski, W. .j.;Purohit, M. .v.;Wilson, J. .r.;Randle Conde, A.;Sekula, S. .j.;Bellis, M.;Burchat, P. .r.;Puccio, E. .m. .t.;Alam, M. .s.;Ernst, J. .a.;Gorodeisky, R.;Guttman, N.;Peimer, D. .r.;Soffer, A.;Spanier, S. .m.;Ritchie, J. .l.;Schwitters, R. .f.;Izen, J. .m.;Lou, X. .c.;Bianchi, F.;De Mori, F.;Filippi, A.;Gamba, D.;Lanceri, L.;Vitale, L.;Martinez Vidal, F.;Oyanguren, A.;Albert, J.;Beaulieu, A.;Bernlochner, F. .u.;King, G. .j.;Kowalewski, R.;Lueck, T.;Nugent, I. .m.;Roney, J. .m.;Tasneem, N.;Gershon, T. .j.;Harrison, P. .f.;Latham, T. .e.;Prepost, R.;Wu, S. .l.
2016
Abstract
We perform the first measurement on the D0-D0 mixing parameters using a time-dependent amplitude analysis of the decay D0→π+π-π0. The data were recorded with the BABAR detector at center-of-mass energies at and near the υ(4S) resonance, and correspond to an integrated luminosity of approximately 468.1 fb-1. The neutral D meson candidates are selected from D∗(2010)+→D0πs+ decays where the flavor at the production is identified by the charge of the low-momentum pion, πs+. The measured mixing parameters are x=(1.5±1.2±0.6)% and y=(0.2±0.9±0.5)%, where the quoted uncertainties are statistical and systematic, respectively.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: http://hdl.handle.net/11384/65254
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
13
8
social impact
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2021-2023 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.