Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
We present measurements of the semileptonic decays B(-) -> D(0)tau(-)(nu) over bar (tau), B(-) -> D*(0)tau(-)(nu) over bar tau, (B) over bar (0) -> D(+)tau(-)(nu) over bar (tau), and (B) over bar (0) -> D*(+)tau(-)(nu) over bar (tau), which are sensitive to non-standard model amplitudes in certain scenarios. The data sample consists of 232 x 10(6) Y(4S) -> B (B) over bar decays collected with the BABAR detector at the PEP-II e(+)e(-) squared to distinguish signalcollider. We select events with a D or D* meson and a light lepton (l = e or mu) recoiling against a fully reconstructed B meson. We perform a fit to the joint distribution of lepton momentum and missing mass (B) over bar -> D(()*())tau(-)(nu) over bar (tau) events from the backgrounds, predominantly R(D*) equivalent to B((B) over bar -> D*tau(-)(nu) over bar (tau))/B((B) over bar -> D*l(-)(nu) over bar (l)) and, from a combined fit to B(-) and (B) over bar (0) channels, obtain the results R(D) = (41.6 +/- 11.7 +/- 5.2)% and R(D*) = (29.7 +/- 5.6 +/- 1.8)%, where the uncertainties are statistical and systematic. Normalizing to measured B(-) -> D(()*()0)l(-)(nu) over bar (l) branching fractions, we obtain B((B) over bar -> D tau(-)(nu) over bar (tau)) = (0.86 +/- 0.24 +/- 0.06)% and B((B) over bar -> D*tau(-)(nu) over bar (tau)) = (1.62 +/- 0.31 +/- 0.10 +/- 0.05)%, where the additional third uncertainty is from the normalization mode. We also present, for the first time, distributions of the lepton momentum vertical bar P(l)*vertical bar, and the squared momentum transfer, q(2).
Measurement of the semileptonic decays (B)over-bar -> D tau(-)(nu)over-bar(tau) and (B)over-bar -> D*tau(-)(nu)over-bar(tau) RID C-5223-2009
We present measurements of the semileptonic decays B(-) -> D(0)tau(-)(nu) over bar (tau), B(-) -> D*(0)tau(-)(nu) over bar tau, (B) over bar (0) -> D(+)tau(-)(nu) over bar (tau), and (B) over bar (0) -> D*(+)tau(-)(nu) over bar (tau), which are sensitive to non-standard model amplitudes in certain scenarios. The data sample consists of 232 x 10(6) Y(4S) -> B (B) over bar decays collected with the BABAR detector at the PEP-II e(+)e(-) squared to distinguish signalcollider. We select events with a D or D* meson and a light lepton (l = e or mu) recoiling against a fully reconstructed B meson. We perform a fit to the joint distribution of lepton momentum and missing mass (B) over bar -> D(()*())tau(-)(nu) over bar (tau) events from the backgrounds, predominantly R(D*) equivalent to B((B) over bar -> D*tau(-)(nu) over bar (tau))/B((B) over bar -> D*l(-)(nu) over bar (l)) and, from a combined fit to B(-) and (B) over bar (0) channels, obtain the results R(D) = (41.6 +/- 11.7 +/- 5.2)% and R(D*) = (29.7 +/- 5.6 +/- 1.8)%, where the uncertainties are statistical and systematic. Normalizing to measured B(-) -> D(()*()0)l(-)(nu) over bar (l) branching fractions, we obtain B((B) over bar -> D tau(-)(nu) over bar (tau)) = (0.86 +/- 0.24 +/- 0.06)% and B((B) over bar -> D*tau(-)(nu) over bar (tau)) = (1.62 +/- 0.31 +/- 0.10 +/- 0.05)%, where the additional third uncertainty is from the normalization mode. We also present, for the first time, distributions of the lepton momentum vertical bar P(l)*vertical bar, and the squared momentum transfer, q(2).
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11384/6790
Citazioni
ND
41
30
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.