The Muon g - 2 experiment, E989, is currently taking data at Fermilab with the aim of reducing the experimental error on the muon anomaly by a factor of four and possibly clarifying the current discrepancy with the theoretical prediction. A central component of this four-fold improvement in precision is the laser calibration system of the calorimeters, which has to monitor the gain variations of the photo-sensors with a 0.04% precision on the short-term (similar to 1 ms). This is about one order of magnitude better than what has ever been achieved for the calibration of a particle physics calorimeter. The system is designed to monitor also long-term gain variations, mostly due to temperature effects, with a precision below the per mille level. This article reviews the design, the implementation and the performance of the Muon g - 2 laser calibration system, showing how the experimental requirements have been met.
The laser-based gain monitoring system of the calorimeters in the Muon g−2 experiment at Fermilab
Lusiani, A.Membro del Collaboration Group
;
2019
Abstract
The Muon g - 2 experiment, E989, is currently taking data at Fermilab with the aim of reducing the experimental error on the muon anomaly by a factor of four and possibly clarifying the current discrepancy with the theoretical prediction. A central component of this four-fold improvement in precision is the laser calibration system of the calorimeters, which has to monitor the gain variations of the photo-sensors with a 0.04% precision on the short-term (similar to 1 ms). This is about one order of magnitude better than what has ever been achieved for the calibration of a particle physics calorimeter. The system is designed to monitor also long-term gain variations, mostly due to temperature effects, with a precision below the per mille level. This article reviews the design, the implementation and the performance of the Muon g - 2 laser calibration system, showing how the experimental requirements have been met.| File | Dimensione | Formato | |
|---|---|---|---|
|
Anastasi_2019_J._Inst._14_P11025.pdf
Accesso chiuso
Tipologia:
Published version
Licenza:
Tutti i diritti riservati
Dimensione
7.64 MB
Formato
Adobe PDF
|
7.64 MB | Adobe PDF | Richiedi una copia |
|
1906.08432v2.pdf
accesso aperto
Tipologia:
Accepted version (post-print)
Licenza:
Non specificata
Dimensione
6.54 MB
Formato
Adobe PDF
|
6.54 MB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.



